Acoustic Glass

Acoustic laminated glass is a premium product featuring a PVB (polyvinyl butyral) acoustic interlayer designed to significantly reduce noise. It works by reflecting and absorbing sound waves, effectively limiting the transmission of sound frequencies between the glass panes and dramatically minimizing noise intrusion.

Compared to standard laminated glass of the same composition, acoustic laminated glass provides superior sound reduction, thanks to the enhanced properties of the acoustic PVB interlayer.

This type of glass is ideal for reducing environmental noise from sources such as ground and air traffic, school playgrounds, industrial areas, and places like bars or factories.

The level of acoustic performance can be customized by adjusting the thickness of the glass and the acoustic PVB interlayer. With a wide range of product options, acoustic laminated glass can meet specific noise reduction requirements for diverse environments.

Comfort, Safety
& Noise Reduction

Rw represents the weighted sound reduction index, measured in decibels, which includes a correction factor to account for human hearing sensitivity. C and Ctr are spectrum adjustments, values added to Rw to account for the specific characteristics of different sound frequencies.

An acoustic Insulated Glazed Unit (IGU) combines all the advantages of laminated glass—such as safety, security, and UV protection—without sacrificing light transmittance. This ensures that you enjoy optimal comfort and protection in your home, while also significantly reducing unwanted noise.

Windows and glazing play a crucial role in noise reduction, and acoustic glass can be further enhanced by integrating other functionalities such as solar control, thermal insulation, and self-cleaning properties.

Soundproof glass
configurator

Easy to use configuration tool:

  • select acoustic IGU by acoustic parameters
  • save configurations to PDF

Noise Simulator

An intuitive-to-use simulator enables:

  • simulation of noise reduction for acoustic IGUs
  • a selection of six types of noise
  • comparison of auditory effects between all acoustic IGUs
  • limiting a comparison to single glass, double or triple IGUs

Specifications

Standard acoustic insulation coefficients
on the basis of

EN 12758 and EN 12354-3
Structure [mm] Acoustic insulation coefficient
at average frequencies [Hz]

R [dB]

Acoustic insulation coefficient and adaptive coefficients

[dB]

125 250 500 1k 2k 4k Rw Ctr C
This chart presents standard values of the weighted acoustic insulation coefficient Rw, as well as the coefficient R for different frequencies of sounds tested for the essential structures of double glazed glass units presented in glass trade magazines and technical publications. Single glass
3 14 19 25 29 33 25 28 -4 -1
4 17 20 26 32 33 26 29 -3 -2
5 19 22 29 33 29 31 30 -2 -1
6 18 23 30 35 27 32 31 -3 -2
8 20 24 29 34 29 37 32 -3 -2
10 23 26 32 31 32 39 33 -3 -2
12 27 29 31 32 38 47 34 -2 0
Laminated glass

Rw– weighted acoustic insulation coefficient

Ctrcorrective coefficient for sound sources containing a large number of low frequencies, for example urban road traffic

C – corrective coefficient for sound sources containing few low frequencies for example high speed road traffic, high speed rail traffic, children playing

6,4 (VSG.33.1) 20 23 29 34 32 38 32 -3 -1
8,8 (VSG 44.2) 20 25 32 35 34 42 33 -3 -1
9,5 (VSG 44.4) 24 26 33 33 35 44 34 -3 -1
Double glazing
4/(6-16)/4 21 17 25 35 37 31 29 -4 -1
6/(6-16)/4 21 20 26 38 37 39 32 -4 -2
6/(6-16)/6 20 18 28 38 34 38 31 -4 -1
8/(6-16)/6 20 21 33 40 36 48 35 -6 -2
10/(6-16)/4 24 21 32 37 42 43 35 -5 -2
10/(6-16)/6 24 24 32 37 37 44 35 -3 -1
6,4 (VSG 33.1)/(6-16)/6 20 19 30 39 37 46 33 -5 -2
6,4 (VSG 33.1)/(6-16)/10 24 25 33 39 40 49 37 -5 -1

Structure [mm] Type of used gas
Acoustic
insulation coefficient
Rw [dB]
C
[dB]
Ctr
[dB]
RA RAtr Acoustic insulation coefficient
at average [Hz] R [dB]
T-Thermofloat 125 250 500 1k 2k 4k
12 Float 35 -1 -3 34 32 29 30 35 31 39 49
12,8 (VSG 66.2) 37 -1 -3 36 34 30 31 35 34 41 51
15 Float 37 -1 -3 36 34 33 32 34 32 44 52
16,8 (VSG 88.2) 39 -1 -3 38 36 33 34 35 35 46 56
12,8 (VSG 66.2) Acoustic 40 -1 -3 39 37 28 32 37 41 41 50
16,8 (VSG 88.2) Acoustic 42 0 -3 42 39 31 35 39 41 46 54

Structure [mm] Type of used gas
Acoustic
insulation coefficient
Rw [dB]
C
[dB]
Ctr
[dB]
RA RAtr Acoustic insulation coefficient
at average [Hz] R [dB]
T-Thermofloat 125 250 500 1k 2k 4k
4/16/4T Argon 31 -2 -5 29 26 25 16 27 41 46 43
6/12/6T Argon 33 -1 -4 32 29 23 19 32 40 30 43
6,4 (VSG 33.1)/16/4T Argon 34 -1 -5 33 29 21 22 31 45 44 48
6/16/4T Argon 34 -1 -5 33 29 26 24 31 45 39 44
8T/16/8 Argon 34 -1 -4 33 30 21 26 33 39 34 46
6/16/6,4T (VSG 33.1T) Argon 35 -3 -7 32 28 22 18 34 43 38 51
6,4 (VSG 33.1)/12/6,4T (VSG 33.1T) Argon 35 -2 -6 33 29 22 20 32 43 41 55
8/16/4T Argon 36 -2 -6 34 30 26 24 34 43 44 46
8/18/4T Argon 36 -1 -5 35 31 24 25 34 43 45 48
8/20/5T Argon 36 -1 -5 35 31 23 25 33 43 40 50
10/16/4T Argon 37 -3 -7 34 30 27 26 35 40 48 50
8/16/6,8T (VSG 33.2T) Argon 37 -2 -6 35 31 18 24 38 44 40 56
8/20/4T Argon 37 -2 -6 35 31 24 26 34 43 45 47
8/16/8,8T (VSG 44.2T) Argon 37 -2 -5 35 32 26 25 36 43 40 54
8,8 (VSG 44.2)/16/4T Argon 37 -1 -5 36 32 28 26 35 44 47 51
8,4 (VSG 44.1)/16/6T Argon 38 -3 -7 35 31 26 28 38 46 38 51
8,8 (VSG 44.2)/12/8,8T (VSG 44.2T) Argon 38 -2 -6 36 32 24 26 36 44 44 61
8/14/6T Argon 38 -1 -5 37 33 22 28 39 44 38 51
10/12/6T Argon 38 -1 -4 37 34 28 27 36 38 40 48
8,8 (VSG 44.2)/16/6T Argon 39 -2 -6 37 34 27 28 38 46 42 56
8,8 (VSG 44.2)/20/6T Argon 39 -2 -5 37 34 24 29 40 45 38 54
8T/16/10 Argon 39 -2 -5 37 34 24 31 39 41 38 51
8,4 (VSG 44.1) Acoustic/16/4T Argon 39 -1 -5 38 34 27 26 36 49 53 55
6,4 (VSG 33.1) Acoustic/16/6T Argon 40 -2 -6 38 34 25 26 37 49 47 58
6/12/8,4T (VSG 44.1T) Acoustic Argon 40 -2 -6 38 34 29 27 37 48 47 56
8,8 (VSG 44.2)/16/6,4T (VSG 33.1T) Argon 40 -2 -6 38 34 26 26 39 47 42 56
9,5 (VSG 44.4)/16/6T Argon 40 -2 -6 38 34 27 32 39 45 41 54
12,8 (VSG 66.2)/12/6T Argon 40 -1 -5 39 35 27 30 37 43 43 57
6,4 (VSG 33.1) Acoustic/12/6,4T (VSG 33.1T) Acoustic Argon 40 -1 -5 39 35 29 27 37 51 59 59
6/16/10,8T (VSG 55.2T) Argon 40 -1 -4 39 36 25 31 36 43 41 53
8/20/8,8T (VSG 44.2T) Argon 40 -1 -4 39 36 27 31 40 44 42 54
8T/16/12 Argon 40 -1 -3 39 37 25 34 40 39 40 52
8,4 (VSG 44.1) Acoustic/16/6T Argon 41 -2 -6 39 35 23 28 40 49 46 59
8,8 (VSG 44.2) Acoustic/16/6,8T (VSG 33.2T) Argon 41 -2 -6 39 35 21 30 42 48 48 56
8/12/8,4T (VSG 44.1T) Acoustic Argon 41 -2 -6 39 35 29 28 38 48 49 60
13,5 (VSG 66.4)/16/8T Argon 41 -1 -5 40 36 31 33 40 42 46 62
6/20/10,8T (VSG 55.2T) Argon 41 -1 -5 40 36 24 34 39 44 42 50
10/16/12,8T (VSG 66.2T) Argon 41 -1 -4 40 37 28 34 41 38 45 58
13,5 (VSG 66.4)/16/12T Argon 41 -1 -4 40 37 32 34 40 38 50 65
8/16/10,8T (VSG 55.2T) Argon 41 -1 -4 40 37 27 31 42 43 41 54
8T/16/10,8 (VSG 55.2) Acoustic Argon 42 -3 -8 39 34 20 32 42 47 46 55
6/16/10,8T (VSG 55.2T) Acoustic Argon 42 -3 -7 39 34 26 29 42 50 47 58
8,8 (VSG 44.2) Acoustic/16/6T Argon 42 -3 -7 39 35 26 30 40 50 47 54
12,8 (VSG 66.2) Acoustic/12/8T Argon 42 -2 -6 40 36 25 32 41 44 45 57
8,8 (VSG 44.2) Acoustic/20/6T Argon 42 -2 -6 40 36 23 30 42 49 44 56
8/16/8,8T (VSG 44.2T) Acoustic Argon 42 -2 -6 40 36 24 29 40 49 49 59
8/20/10,8 (VSG 55.2) Argon 42 -2 -5 40 37 25 33 40 43 42 58
10/24/8,8T (VSG 44.2T) Argon 42 -1 -4 41 38 30 35 42 42 44 61
9,5 (VSG 44.4)/16/12,8T (VSG 66.2T) Argon 43 -2 -7 41 36 25 35 43 44 46 62
12,8 (VSG 66.2)/12/8,8T (VSG 44.2T) Argon 43 -2 -6 41 37 26 32 42 47 48 59
6/20/10,8T (VSG 55.2T) Acoustic Argon 43 -2 -6 41 37 25 34 43 50 45 58
8,8 (VSG 44.2) Acoustic/12/8,8T (VSG 44.2T) Argon 43 -2 -6 41 37 26 32 42 51 54 61
10/14/16,8T (VSG 88.2T) Argon 43 -2 -4 41 39 29 38 42 38 45 56
12,8 (VSG 66.2) Acoustic/12/10T Argon 43 -1 -5 42 38 28 36 43 43 47 57
8/16/10,8T (VSG 55.2T) Acoustic Argon 44 -3 -7 41 37 27 32 43 49 47 58
8/20/8,4T (VSG 44.1T) Acoustic Argon 44 -2 -6 42 38 29 31 43 49 50 57
16,8 (VSG 88.2) Acoustic/12/10T Argon 44 -1 -4 43 40 30 39 44 42 48 57
8,8T (VSG 44.2T) Acoustic/16/8,8T (VSG 44.2T) Acoustic Argon 45 -3 -8 42 37 21 34 46 52 54 57
10,8 (VSG 55.2) Acoustic/12/8,8T (VSG 44.2T) Acoustic Argon 45 -2 -7 43 38 30 33 43 53 57 67
10/16/8,8T (VSG 44.2T) Acoustic Argon 45 -2 -6 43 39 27 36 44 47 52 60
10/16/12,8T (VSG 66.2T) Acoustic Argon 45 -1 -4 44 41 33 36 44 46 48 57
9,5 (VSG 44.4)/20/8,8T (VSG 44.2T) Acoustic Argon 46 -3 -7 43 39 29 36 43 50 52 60
10/20/8,8T (VSG 44.2T) Acoustic Argon 46 -1 -5 45 41 27 35 44 48 54 60
10/20/10,8T (VSG 55.2T) Acoustic Argon 46 -1 -4 45 42 33 37 44 47 49 57
12,8 (VSG 66.2) Acoustic/16/8,8T (VSG 44.2T) Acoustic Argon 47 -2 -7 45 40 26 39 46 51 54 61
11,5 (VSG 55.4)/20/13,5 (VSG 66.4) Argon 47 -1 -4 46 43 38 39 46 46 51 68
13,5T (VSG 66.4T) Acoustic/14/12,8T (VSG 66.2T) Acoustic Argon 48 -2 -6 46 42 28 39 48 51 52 60
16,8 (VSG 88.2) Acoustic/16/12,8T (VSG 66.2T) Acoustic Argon 50 -1 -4 49 46 37 39 47 51 53 61
12,8 (VSG 66.2) Acoustic/20/8,8T (VSG 44.2T) Acoustic Argon 51 -2 -7 49 44 30 41 48 56 55 62
15,5 (VSG 68.4) Acoustic/15/16,8T (VSG 88.2T) Acoustic Argon 51 -1 -4 50 47 39 40 47 51 55 62
16,8 (VSG 88.2) Acoustic/20/12,8T (VSG 66.2T) Acoustic Argon 51 -1 -3 50 47 41 45 49 49 56 71

Structure [mm] Type of used gas
Acoustic
insulation coefficient
Rw [dB]
C
[dB]
Ctr
[dB]
RA RAtr Acoustic insulation coefficient
at average [Hz] R [dB]
T-Thermofloat 125 250 500 1k 2k 4k
4T/10 Termo/4/10 Termo/4T Argon 31 -1 -5 30 26 24 19 27 42 50 46
4T/12/4/12/4T Argon 33 -2 -5 31 28 17 23 29 43 51 44
6T/12/3/12/4T Argon 35 -2 -7 33 28 20 24 31 45 45 47
6T/12/6/12/6T Argon 35 -2 -7 33 28 14 25 34 45 40 56
4T/12/4/12/6,4T (VSG 33.1T) Argon 35 -1 -6 34 29 16 25 32 47 50 55
8,8T (VSG 44.2T)/12/4/12/4T Argon 36 -2 -7 34 29 20 24 36 47 51 54
6,4T (VSG 33.1T)/12/6/12/4T Argon 36 -2 -6 34 30 21 25 32 46 46 53
6T/12/4/12/4T Argon 36 -2 -6 34 30 18 26 32 47 48 48
6T/12/5/12/4T Argon 36 -2 -6 34 30 20 24 32 46 45 49
6,4T (VSG 33.1T)/12/4/12/6,4T (VSG 33.1T) Argon 37 -3 -8 34 29 12 27 35 47 43 59
6,4T (VSG 33.1T) Acoustic/12/6/12/4T Argon 37 -2 -6 35 31 18 25 35 50 56 57
8T/12/6/12/6T Argon 37 -2 -6 35 31 16 25 39 46 36 56
8T/12/4/12/6T Argon 38 -1 -5 37 33 21 29 37 43 40 56
8,8T (VSG 44.2T)/12/4/12/8,8T (VSG 44.2T) Argon 39 -3 -8 36 31 19 29 39 47 48 64
8T/12/8/12/6,8T (VSG 33.2T) Argon 39 -3 -8 36 31 15 27 38 48 44 63
8,8T (VSG 44.2T)/12/4/12/6,4T (VSG 33.1T) Argon 39 -2 -8 37 31 17 28 39 49 44 62
10/12/6/12/4 Argon 39 -2 -7 37 32 18 29 36 42 48 54
8,8T (VSG 44.2T)/12/6/12/8,8T (VSG 44.2T) Argon 40 -3 -8 37 32 20 30 39 47 46 63
6T/14/4/14/ 9,5T (VSG 44.4T) Argon 40 -2 -8 38 32 17 32 40 49 43 60
6T/12/6/12/8,8T (VSG 44.2T) Argon 40 -2 -7 38 33 20 29 39 47 43 57
9,5T (44.4T)/12/6/12/6T Argon 40 -2 -7 38 33 19 28 40 50 42 59
6T/12/4/12/8,8T (VSG 44.2T) Argon 41 -3 -8 38 33 16 33 41 51 51 60
6T/12/6/12/8,8T (VSG 44.2T) Acoustic Argon 41 -3 -8 38 33 17 31 41 51 49 59
10T/14/4/14/6T Argon 41 -1 -6 40 35 22 36 40 43 41 55
8,8T (VSG 44.2T) Acoustic/12/6/12/4T Argon 41 -1 -5 40 36 22 29 40 50 52 52
8T/14/4/14/8,4T (VSG 44.1T) Argon 41 -1 -5 40 36 29 30 39 46 43 55
8T/12/4/12/10,8T (VSG 55.2T) Argon 42 -2 -6 40 36 21 33 42 44 44 63
6T/12/4/12/8,8T (VSG 44.2T) Acoustic Argon 42 -1 -6 41 36 23 33 39 51 50 60
8T/12/6/12/8,8T (VSG 44.2T) Argon 43 -3 -8 40 35 19 33 44 48 49 56
6T/12/6/12/10,8T (VSG 55.2T) Argon 43 -2 -7 41 36 21 33 43 51 48 57
8T/12/6/12/8,8T (VSG 44.2T) Acoustic Argon 43 -2 -7 41 36 23 31 42 50 51 65
6,4T (VSG 33.1T) Acoustic/12/4/12/6,4T (VSG 33.1T) Acoustic Argon 43 -2 -6 41 37 25 30 40 53 57 61
8T/12/6/12/10,8T (VSG 55.2T) Argon 43 -2 -6 41 37 24 34 41 46 47 60
8/16/6/16/10,8 (VSG 55.2) Argon 43 -2 -5 41 38 26 33 42 43 44 53
12,8T (VSG 66.2T)/12/6/12/6T Argon 43 -1 -6 42 37 27 34 41 47 45 61
8,8T (VSG 44.2T) Acoustic/12/6/10/10 Argon 44 -3 -8 41 36 24 34 43 49 52 64
8T/12/8/12/10,8T (VSG 55.2T) Argon 44 -3 -7 41 37 21 33 45 50 48 57
8T/12/6/12/10,8T (VSG 55.2T) Acoustic Argon 44 -2 -7 42 37 23 32 43 49 47 65
12,8T (VSG 66.2T)/16/4/16/6T Argon 44 -2 -6 42 38 30 38 42 46 46 56
8T/14/4/14/8,8T (VSG 44.1T) Acoustic Argon 44 -1 -5 43 39 29 31 40 49 49 58
10,8T (VSG 55.2T) Acoustic/16/6/16/8T Argon 45 -2 -7 43 38 27 33 44 51 51 67
9,5T (VSG 44.4T)/14/4/14/9,5T (VSG 44.4T) Acoustic Argon 45 -2 -7 43 38 27 35 45 52 51 65
8/16/6/16/10,8 (VSG 55.2) Acoustic Argon 45 -2 -5 43 40 28 33 45 49 46 55
8T/16/6/16/12,8T (VSG 66.2T) Argon 45 -1 -5 44 40 29 38 45 43 48 58
10T/12/6/12/12,8T (VSG 66.2T) Acoustic Argon 46 -2 -6 44 40 28 38 45 46 49 67
6,4T (VSG 33.1T)/12/4/12/26,6 Pyrobel 25 Argon 46 -2 -6 44 40 35 39 44 48 55 59
8T/16/6/16/12,8T (VSG 66.2T) Acoustic Argon 46 -2 -6 44 40 25 36 45 49 50 60
9,5T (VSG 44.4T)/18/4/15/8,8T (VSG 44.2T) Acoustic Argon 47 -2 -8 45 39 26 37 48 53 53 56
8,4T (VSG 44.1T) Acoustic/12/4/12/8,4T (VSG 44.1T) Acoustic Argon 47 -2 -6 45 41 28 34 44 53 57 61
8,4T (VSG 44.1T) Acoustic/12/6/12/8,4T (VSG 44.1T) Acoustic Argon 47 -2 -6 45 41 28 34 45 53 56 61
8,8T (VSG 44.2T) Acoustic/12/6/12/8,4T (VSG 44.1T) Acoustic Argon 47 -2 -6 45 41 28 34 45 52 56 62
8,8T (VSG 44.2T) Acoustic/12/6/12/8,8T (VSG 44.2T) Acoustic Argon 47 -2 -6 45 41 28 33 46 53 56 61
9,5T (VSG 44.4T)/12/6/12/8,8T (VSG 44.2T) Acoustic Argon 47 -2 -6 45 41 28 35 44 52 55 61
9,5T (VSG 44.4T)/12/8/12/8,8T (VSG 44.2T) Acoustic Argon 47 -2 -6 45 41 29 34 46 52 55 60
10/16/6/16/10,8 (VSG 55.2) Acoustic Argon 47 -2 -5 45 42 30 37 45 48 48 56
13,5T (VSG 66.4T) Acoustic/14/4/14/9,5T (VSG 44.4T) Argon 47 -1 -5 46 42 31 37 47 51 48 56
12,8T (VSG 66.2T)/16/4/16/9,5T (VSG 44.4T) Argon 47 -1 -4 46 43 32 39 46 47 49 61
8,8T (VSG 44.2T) Acoustic/12/6/12/12,8T (VSG 66.2T) Acoustic Argon 48 -3 -8 45 40 24 40 47 53 55 60
8,8T (VSG 44.2T) Acoustic/12/8/12/8,4T (VSG 44.1T) Acoustic Argon 48 -2 -7 45 41 26 35 47 53 57 61
8,8T (VSG 44.2T) Acoustic/12/8/12/8,8T (VSG 44.2T) Acoustic Argon 48 -2 -7 46 41 28 35 47 54 57 61
10,8T (VSG 55.2T) Acoustic/12/6/12/8,8T (VSG 44.2T) Acoustic Argon 48 -2 -6 46 42 29 35 46 54 56 62
13,5T (VSG 66.4T) Acoustic/14/4/12/11,5T (VSG 55.4T) Argon 48 -1 -4 47 44 33 40 48 49 49 56
12,8T (VSG 66.2T)/16/4/16/27,8T P8B Argon 48 -1 -3 47 45 32 39 46 47 49 61
12,8T (VSG 66.2T)/16/4/18/23T P7B Argon 49 -2 -4 47 45 39 44 48 43 54 63
15,5T (VSG 68.4T) Acoustic/12/4/12/15T (VSG 66.8T) Acoustic Argon 50 -1 -3 50 47 37 43 49 50 53 59
13,5T (VSG 66.4T) Acoustic/14/8/12/13,5T (VSG 66.4T) Acoustic Argon 51 -1 -4 50 47 37 43 51 52 53 61
15,5 (VSG 68.4) Acoustic/15/4/12/16,8T (VSG 88.2T) Acoustic Argon 52 -1 -3 51 49 42 43 51 52 55 70

Additionally, Press Glass offers a wide range of alternative specifications available from the PRESS GLASS group.